Accidental safety analysis methodology development in decommission of the nuclear facility
Creators
- 1. Seoul National Univ., Seoul (Korea, Republic of)
Description
Decontamination and Decommissioning (D and D) of a nuclear reactor cost about 20% of construction expense and production of nuclear wastes during decommissioning makes environmental issues. Decommissioning of a nuclear reactor in Korea is in a just beginning stage, lacking clear standards and regulations for decommissioning. This work accident safety analysis in decommissioning of the nuclear facility can be a solid ground for the standards and regulations. For source term analysis for Kori-1 reactor vessel, MCNP/ORIGEN calculation methodology was applied. The activity of each important nuclide in the vessel was estimated at a time after 2008, the year Kori-1 plant is supposed to be decommissioned. And a methodology for risk analysis assessment in decommissioning was developed
Availability note (English)
Available from INIS in electronic form; Also available from KINSFiles
38059513.pdf
Files
(1.7 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:9d558f65f98c7448d29f4464380f448c
|
1.7 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 95 p.
- Report number
- KINS/HR--445
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 38059513
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CONSTRUCTION; DECOMMISSIONING; DECONTAMINATION; KORI-1 REACTOR; REACTOR VESSELS; REACTORS; REGULATIONS
- Descriptors DEC
- CLEANING; CONTAINERS; ENRICHED URANIUM REACTORS; LAWS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 15 refs, 31 figs, 11 tabs