Published May 1, 1997 | Version v1
Journal article

A simple method to stabilize the prostate during transperineal prostate brachytherapy

Description

Purpose: The authors report a simple, remarkably effective method to limit prostatic motion during prostate brachytherapy. Methods and Materials: Two 18-ga. stainless-steel needles (the same type used for source placement) are inserted transperineally, obliquely into the prostate, using finger and fluoroscopic guidance. These needles are left in place during the implant procedure. In our experience, maximum lateral displacement is decreased from about 1 cm to 0.2 mm, while craniocaudal motion is virtually eliminated. Conclusion: The method described here is simple to perform and does not require specialized equipment

Additional details

Identifiers

PII
S0360301696005810;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
38
Journal Issue
2
Journal Page Range
p. 341-342
ISSN
0360-3016
CODEN
IOBPD3

Optional Information

Copyright
Copyright (c) 1997 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.