Published 1974
| Version v1
Report
Open
Time-interval selection circuits
Description
Circuits for the isolation of particles which are separated by a time interval greater than the assigned one are described. The circuits are designed to reduce the hum level when working with spark and proportional chambers and pulse amplitude analysis systems in intensive particle beams
Availability note (English)
MF available from INIS under the Report Number.Files
8281933.pdf
Files
(125.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:5f6bc0ce5f6d18e97796c0abcb36ac96
|
125.1 kB | Preview Download |
System files
(10.0 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Схемы выделения интервалов времени
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- IFVE-SEF--74-107
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 8281933
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- INTEGRATED CIRCUITS; LOGIC CIRCUITS; MULTIVIBRATORS; PROPORTIONAL COUNTERS; PULSE ANALYZERS; RESPONSE FUNCTIONS; SPARK CHAMBERS; TIME INTERVAL ANALYZERS; TIME MEASUREMENT; TIME RESOLUTION; TIME-TO-AMPLITUDE CONVERTERS
- Descriptors DEC
- ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; FUNCTIONS; GAS TRACK DETECTORS; MEASURING INSTRUMENTS; PULSE CIRCUITS; PULSE CONVERTERS; RADIATION DETECTORS; RESOLUTION; TIMING PROPERTIES
Optional Information
- Notes
- 4 refs.; 2 figs.; submitted to the journal Instrum. Exp. Tech.