Published July 1987 | Version v1
Journal article

Application of real-time 3-D SAFT in the tandem mode

  • 1. Battelle Pacific Northwest Labs., Richland, WA (USA)

Description

This paper presents a description of what tandem SAFT is as contrasted with pulse-echo SAFT. The implementation of tandem SAFT is far more complicated than pulse-echo SAFT and puts greater demands on computer processing speed and/or virtual computer memory capacity. Tandem SAFT has been implemented by using look-up tables for determining path lengths so that no computations are needed during processing. Furthermore, the tandem SAFT has been developed for operation on a special-purpose parallel processor so that speeds of 10 A-scans/s can be achieved. A series of studies have been made of system performance showing resolution performance, effects of saturation on imaging, defect orientation effects, sizing criteria, and difficulties encountered on thin specimens when using tandem SAFT. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Eng. Des.
Journal Volume
102
Journal Issue
3
Series
Nucl. Eng. Des.
Journal Page Range
387-396
ISSN
0029-5493
CODEN
NEDEA

Conference

Title
12. MPA seminar on safety and reliability of pressure components with special emphasis on nuclear technology.
Dates
9-10 Oct 1986.
Place
Stuttgart (Germany, F.R.).

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
18095369
Subject category
S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
IMAGE PROCESSING; PIPES; PRESSURE VESSELS; ULTRASONIC TESTING
Descriptors DEC
ACOUSTIC TESTING; CONTAINERS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING

Optional Information

Contract/Grant/Project number
Contract DE-AC06-76RLO1830 NRC FIN B2467