To support the installation and use of elbow meters to measure the high pressure emergency coolant injection flow in an operating nuclear station, a test program was performed to qualify: (i) the 'hot' tapping procedure for field application and (ii) the use of elbow meters for accurate flow measurements over the full range of station ECI flow conditions. This paper describes the design conditions and major components of a flow loop used for the elbow meter calibrations. Typical test results are presented and discussed. (authors)
Additional details
Publishing Information
- Publisher
- American Society of Mechanical Engineers - ASME
- Imprint Place
- New York (United States)
- Imprint Pagination
- 6 p.
Conference
- Title
- 14. international conference on nuclear engineering (ICONE 14)
- Dates
- 17-20 Jul 2006
- Place
- Miami, FL (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- France
- INIS RN
- 39019607
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCIDENTS; CALIBRATION; COOLANTS; DESIGN; INSTALLATION; METERS; NUCLEAR POWER PLANTS; PRESSURE GAGES