Published February 15, 2006 | Version v1
Miscellaneous

The Performance of a CsI-BGO Based Anti compton Spectrometer

  • 1. Nuclear Research Center- Negev, Beer Sheva (Israel)

Description

In the search for mobile systems for remote sensing of gamma radiation with improved sensitivity to low intensity radioactive sources in the background, we developed a Compton suppressed scintillation detector based on a CsI(Tl) main spectrometer surrounded by a BGO cylinder. The performance of the system was evaluated by measuring the spectra of several radioactive sources and natural background, with the Anti Compton condition on and off . The performance of the system was compared to that of the NANOSPEC 2''*2'' CsI(Tl) spectrometer by TARGET. The performance of the CsI-BGO system was found to be better then that of NANOSPEC by nearly a factor of 2. Theoretical simulations indicate that a further 30% improvement is achievable

Part of:
The 23. conference of the Nuclear Societies in Israel. Book of articles

Additional details

Publishing Information

Imprint Title
The 23. conference of the Nuclear Societies in Israel. Book of articles
Imprint Pagination
256 p.
Journal Page Range
p. 162-164
Report number
INIS-IL--012

Conference

Title
23. conference of the Nuclear Societies in Israel
Dates
15-16 Feb 2006
Place
Dead Sea (Israel)

Optional Information