Published 1993 | Version v1
Report

Choice of hexapole parameters for ECR ion source

  • 1. D.V. Efremov Scientific Research Institute of Electrophysical Apparatus, St. Petersburg (Russian Federation)

Description

Some results of optimization of Nd Fe B hexapole parameters, carried out on the base of analytical and numerical calculations for a 14 GHz compact ECR ion source are presented. On providing the required value and distribution of magnetic field it has been enabled to minimize the magnetized volume of the hexapole. The number of bars and outer radii of Halbach hexapole magnetic rings at fixed inner radius, defined by outer radius of the plasma chamber, have been varied

Additional details

Publishing Information

Imprint Title
Proceedings of the 1993 Particle Accelerator Conference: Volume 4
Imprint Pagination
738 p.
Journal Page Range
p. 3205-3206.
Report number
DOE/ER/40779--1-Vol.4

Conference

Title
international particle accelerator conference.
Acronym
PAC '93
Dates
17-20 May 1993.
Place
Washington, DC (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
26025295
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ELECTRON CYCLOTRON-RESONANCE; HEXAPOLAR CONFIGURATIONS; ION SOURCES; MAGNETIC FIELD CONFIGURATIONS; OPTIMIZATION
Descriptors DEC
CLOSED CONFIGURATIONS; CYCLOTRON RESONANCE; MULTIPOLAR CONFIGURATIONS; RESONANCE

Optional Information

Secondary number(s)
CONF-930511--Vol.4.