Published February 1976
| Version v1
Report
Restricted
235U fission product decay heat from 1 to 100,000 seconds. Final report
Description
This report is on project 392-1. The absorbable components of the fission-product decay heat from thermal-neutron fission of 235U have been measured in the 1 to 100,000 second time range for a one-day (86,400 second) irradiation time. The systematic uncertainty of the measurement is 2.4%, with statistical uncertainties of 2% at 1 second, increasing to 4% at 100,000 seconds. The measurements were made using a nuclear calorimeter which is based on a large (4000 liter) liquid scintillator. The uranium irradiations were made in a water moderated 252Cf source with a rapid pneumatic system to transfer the irradiated sample to the scintillator
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS. $4.50.
Files
Additional details
Publishing Information
- Imprint Pagination
- 56 p.
- Report number
- PB--255745
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8323814
- Subject category
- S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
- Descriptors DEI
- AFTER-HEAT; DECAY; ENERGY; FISSION PRODUCTS; THERMAL FISSION; URANIUM 235
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; BARYON REACTIONS; EVEN-ODD NUCLEI; FISSION; HADRON REACTIONS; HEAVY NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MINUTES LIVING RADIOISOTOPES; NEUTRON REACTIONS; NUCLEAR REACTIONS; NUCLEI; NUCLEON REACTIONS; RADIOACTIVE MATERIALS; RADIOISOTOPES; URANIUM ISOTOPES; YEARS LIVING RADIOISOTOPES