Published March 2006 | Version v1
Journal article

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

  • 1. Shahid Sadoghi University of Medical Sciences, Department of Medical Physics, Yazd(Iran, Islamic Republic of)
  • 2. Isfahan University of Medical Sciences, Department of Medical Physics, Isfahan(Iran, Islamic Republic of)

Description

While the benefits of Computed Tomography are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiological procedures. Is the reduction of exposures by requiring optimization of CT procedures [a principle concern in radiological protection]? In this study, the radiation dose of conventional and spiral CT were investigated and compared with European Commission Reference Dose Levels Materials and Methods: 'The dosimetric quantities proposed in the European Guidelines for CT are Weighted Computed Tomography Dose Index (Weighted Computed Tomography Dose Index ) for a single slice for axial scanning or per rotation for helical scanning and Dose-Length Product for a complete examination. The patient-related data were collected for brain, neck, chest, abdomen and pelvis examinations in each scanner. For each type of examination, 10 typical patients were randomly included. CTDI with an active length of 10cm was measured in two CT scanners by using UNFORS (Mult-O-Meter 601) in head and body phantom (PMMA) with 16 cm and 32 cm in diameter; respectively. Mean values of Weighted Computed Tomography Dose Index , Dose-Length Product and Effective Dose were estimated for those examinations. Results: Weighted Computed Tomography Dose Index had a range of 15.8-24.7 mGy for brain, 16.1-30.6 mGy for neck, 6.8-9.2 mGy for chest, 6.8-9.8 mGy for abdomen and pelvis. Dose-Length Product had a range of 246.4-397.7 mGy.cm for brain, 104.6-262.2 mGy.cm for neck, 135- 248.4 mGy.cm for chest, 187-298.9 mGy.cm for abdomen and 197.2-319.4 mGy.cm for pelvis. The mean values of effective dose were 0.70 mSv for brain, 1 mSv for neck, 3.2 mSv for chest, 3.3 mSv for abdomen and 5.1 mSv for pelvis. Conclusion : The obtained results in this study have shown that Weighted Computed Tomography Dose Index and Dose-Length Product are lower than Dose-Length Product and other studies, in other words, the performance of all scanners has been satisfactory as far as Weighted Computed Tomography Dose Index and Dose-Length Product are concerned. The Weighted Computed Tomography Dose Index and Dose-Length Product in the conventional CT are higher than the spiral CT values. With regard to ALARA principle, for the establishment of reference dose levels, the radiation dose with spiral CT scanners should be taken into account

Availability note (English)

Available from Atomic Energy Organization of Iran

Additional details

Publishing Information

Journal Title
Iranian Journal of Radiation Research (Print)
Journal Volume
3
Journal Issue
no.4
Journal Page Range
p. 183-189
ISSN
1728-4554

INIS

Country of Publication
Iran, Islamic Republic of
Country of Input or Organization
Iran, Islamic Republic of
INIS RN
37120036
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; IMAGE SCANNERS; PATIENTS; RADIATION DOSES; RADIATION PROTECTION; SPIRAL CONFIGURATION
Descriptors DEC
CONFIGURATION; DIAGNOSTIC TECHNIQUES; DOSES; EVALUATION; PROCESSING; TOMOGRAPHY