Published February 2005 | Version v1
Journal article

The use of liquid scintillation spectrometry as a very sensitive radioanalytical tool for the determination of alpha, beta and monochromatic electron emitting impurities in radiopharmaceutical compounds

  • 1. Universita degli Studi di Milano (Italy). Radiochemistry Lab.

Description

Many labeled compounds are used as radiopharmaceuticals (RP), for emission imaging and metabolic radiotherapy and contain as labeling agents γ, β-, β+, monochromatic e- and α emitting radionuclides (RN). These labeled compounds very often contain unexpected radionuclidic impurities. Some long-lived isotopic and non-isotopic impurities lead to undesirable radiation doses to the patient and his relatives, as well as to medical/paramedical personnel, other than the general population, due to rad-waste of contaminated specimen and excretion of biological fluids. Use was made of liquid scintillation counting/spectrometry (LSCS) for the detection of tiny amounts of charged particle emitting impurities in RPs labeled with 64Cu, 67Ga, 90Y, 90Sr/90Y, 123I, 153Sm, 177Lu and 201Tl. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
263
Journal Issue
2
Journal Page Range
p. 521-525
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
31 refs.