Published June 1989 | Version v1
Journal article

Use of thermal probe for potential measurement in vacuum and in decompensated electron beams

  • 1. Moscow Engineering Physics Institute (USSR)

Description

It is shown that a thermal probe can be used to measure potential in vacuum tubes with and without an electron beam. A method is proposed for allowance for the minimization of the errors produced by field distortion from the leads of the probe. The measured fields in a mock-up of an electron source differed from the computer-calculated values by not more than 6%

Additional details

Publishing Information

Journal Title
Instruments and Experimental Techniques (English Translation)
Journal Volume
31
Journal Issue
6
Series
Instrum. Exp. Tech. (Engl. Transl.).
Journal Page Range
1524-1528
ISSN
0020-4412
CODEN
INETA

Optional Information

Notes
Cover-to-cover translation of Pribory i Tekhnika Ehksperimenta (USSR).