Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system
Creators
- 1. Faculdade de Farmácia, Universidade Federal de Goiás, 74605-220, Goiânia, Goiás (Brazil)
- 2. Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Rod MGT 367-Km 583, Diamantina, MG (Brazil)
- 3. Departamento Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Rod MGT 367-Km 583, Diamantina, MG (Brazil)
- 4. Programa Multicêntrico de Pós Graduação em Ciências Fisiológicas (PMPGCF), Universidade Federal dos Vales do Jequitinhonha e Mucuri, 39100-000, Diamantina, MG (Brazil)
Description
Cotinine (CO) is the principal metabolite of nicotine, and it is used as a biomarker to monitor the exposure of an individual to tobacco. This paper sought to present the use of a boron-doped diamond (BDD) electrode for the electrochemical characterization of CO by voltammetric techniques and its quantification in saliva samples by multiple-pulse amperometry (MPA) in a flow injection analysis (FIA) system. In phosphate buffer solution 0.1 mol L−1 (pH 7), the CO presented two electrochemical processes, one anodic at +1.8 V and one cathodic at −1.2 V (vs. Ag/AgCl). The second process was dependent on the first and both processes were irreversible. It was found that CO electrochemical processes are controlled by diffusion and that two-protons and two-electrons are involved in the oxidation reaction. In determination of CO in saliva samples, the MPA detection was used, applying four potential pulses: (1) at +1.8 V/400 ms, generator potential pulse for oxidation of CO; (2) at −1.0 V/500 ms, potential pulse for remove possible interferents; (3) at −1.2 V/30 ms, collector potential pulse for reduction of the product generated and CO quantification; (4) 1.45 V/300 ms, potential pulse for cleaning BDD electrode. The proposed method attained an analytical frequency of 36 determinations per hour with a relative standard deviation of 1.47% for 10 measurements of 1.0 × 10−5 mol L−1 CO. A good linear range from 0.5 to 100 μmol L−1 was obtained with a detection limit for CO estimated at 0.06 μmol L−1. Approximately 100% of the CO added to saliva samples was recovered. Therefore, this work presents, for the first time, the electrochemical behavior of the CO at an electrode as well as a simple, fast and low-cost method for monitoring the degree of exposure to tobacco by CO determination in saliva samples using the FIA-MPA technique.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.electacta.2016.10.177Additional details
Identifiers
- DOI
- 10.1016/j.electacta.2016.10.177;
- PII
- S0013-4686(16)32286-1;
Publishing Information
- Journal Title
- Electrochimica Acta
- Journal Volume
- 222
- Journal Page Range
- p. 331-337
- ISSN
- 0013-4686
- CODEN
- ELCAAV
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 49020208
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- AMPEROMETRY; BORON; COBALT; DIAMONDS; DOPED MATERIALS; ELECTROCHEMISTRY; ELECTRODES; PULSES; SALIVA; SILVER CHLORIDES
- Descriptors DEC
- BIOLOGICAL MATERIALS; BODY FLUIDS; CARBON; CHEMICAL ANALYSIS; CHEMISTRY; CHLORIDES; CHLORINE COMPOUNDS; ELEMENTS; HALIDES; HALOGEN COMPOUNDS; MATERIALS; METALS; MINERALS; NONMETALS; QUANTITATIVE CHEMICAL ANALYSIS; SEMIMETALS; SILVER COMPOUNDS; SILVER HALIDES; TITRATION; TRANSITION ELEMENT COMPOUNDS; TRANSITION ELEMENTS; VOLUMETRIC ANALYSIS
Optional Information
- Copyright
- Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.