Published April 1999 | Version v1
Journal article

Quality control and clinical application of two bone imaging 99mTc radiopharmaceuticals

  • 1. Institute for Nuclear Research and Nuclear Energy, Sofia (Bulgaria)
  • 2. National Oncological Centre, Sofia (Bulgaria)

Description

The radiochemical purity of MDP and HEDP has been determined by means of gel chromatography on Sephadex and thin layer chromatography on plastic foil silica gel. The comparison of the two radiopharmaceuticals shows equal level of complex formation with 99mTc. The biodistribution demonstrated that the application of HEDP allows earlier scanning than MDP. MDP and HEDP show equal effectivity during the clinical investigations. There is no significant difference in the radiochemical purity within six hours after the reconstitution of the freeze-dried kits. HEDP kit demonstrates shorter period of accumulation and equivalent complex formation levels, so it can be used in routine nuclear medicine diagnostics together with MDP kit. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
240
Journal Issue
1
Journal Page Range
p. 349-352
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
6 refs.