Published April 1982 | Version v1
Report Open

Evaluation of SCC test methods for Inconel 600 in low temperature aqueous solutions

Description

In late 1981, widespread leakage was encountered in Alloy 600 steam-generator tubing at the Three Mile Island Unit 1 nuclear power plant. The phenomenon was identified as low-temperature intergranular stress-corrosion cracking (SCC) initiated from the inner surfaces of the tubes exposed to the primary coolant. A testing program was initiated to examine the material and environmental factors relevant to these failures, which were found to be associated with sensitization of the material and contamination of the coolant by air and sodium thiosulfate. The test solutions contained 1.3% boric acid with various additions of sulfur compounds and lithium hydroxide. Constant extension rate testing was used as the primary tool to examine environmental effects such as the inhibition of cracking by lithium hydroxide. Important effects of crack-initiation frequency on the specimen potential (and therefore crack velocity) are demonstrated

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE83011358.