A simplified model of Passive Containment Cooling System in a CFD code
Creators
- 1. Science and Technology on Reactor System Design Technology Laboratory, Chengdu (China)
- 2. CEA/LATF, 91191 Gif-sur-Yvette (France)
Description
Highlights: ► We have built a condensing model using Navier–Stokes equations in CAST3M code. ► We have done a benchmark work on the condensing model using the COPAIN tests data. ► We have built an evaporating model according to Aiello's model in CAST3M code. ► We used Kang and Park's film evaporation tests data to validate the model. ► An integrated model was derived by coupling two individual models with a steel plate. -- Abstract: In this paper, we built up a simplified model of the Passive Containment Cooling System in a CFD code, including a steel plate, a condensing channel and an evaporating channel. In the inner side of the plate, the condensing channel is supposed to be the source of heat transfer into the steel plate. Along the outer side, an evaporating falling film is used to extract the heat from the steel plate. Upward flow of air is also considered along the evaporating film. In the condensing channel, a flow solver based on an asymptotic model of the Navier–Stokes equations at the low Mach number regime and two turbulence models (Buleev's model and Chien's k–ε model) are considered. The condensing channel model was used to model the COPAIN test, the computed heat flux and condensation rate were compared with the experimental data. In the evaporating channel, a simplified model developed by Aiello and Ciofalo (2009) was used, which considered the heat and mass balance between the falling film and the ascending air flow. The model was validated for two cases: a dry wall case and a completely wet wall case. In the former case, the results were compared with 2D predictions obtained by using the CFX-4 CFD code. In the latter case, the results were compared with experimental data obtained by Kang and Park. The comparison showed a satisfactory agreement on heat transfer rates, despite some overprediction depending on the air velocity. At the end, the condensing channel model and the evaporating channel model were coupled by the steel plate to establish the complete model for the PCCS. In the absence of relative tests, a case with general parameter values was implemented in the complete model
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nucengdes.2013.06.010Additional details
Identifiers
- DOI
- 10.1016/j.nucengdes.2013.06.010;
- PII
- S0029-5493(13)00315-4;
Publishing Information
- Journal Title
- Nuclear Engineering and Design
- Journal Volume
- 262
- Journal Page Range
- p. 579-588
- ISSN
- 0029-5493
- CODEN
- NEDEAU
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45070345
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- AIR FLOW; ASYMPTOTIC SOLUTIONS; COMPARATIVE EVALUATIONS; COMPUTERIZED SIMULATION; CONTAINMENT; COOLING SYSTEMS; EXPERIMENTAL DATA; FILMS; FLUID MECHANICS; HEAT; HEAT FLUX; HEAT TRANSFER; MACH NUMBER; MASS BALANCE; PLATES; STEELS; TURBULENCE
- Descriptors DEC
- ALLOYS; CARBON ADDITIONS; DATA; DIMENSIONLESS NUMBERS; ENERGY; ENERGY SYSTEMS; ENERGY TRANSFER; EVALUATION; FLUID FLOW; GAS FLOW; INFORMATION; IRON ALLOYS; IRON BASE ALLOYS; MATHEMATICAL SOLUTIONS; MECHANICS; NUMERICAL DATA; SIMULATION; TRANSITION ELEMENT ALLOYS; VELOCITY
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.