Published October 2022 | Version v1
Journal article

Influence of nuclear data library on neutronics benchmark of China experimental fast reactor start-up tests

  • 1. Shanghai Jiao Tong University, Shanghai, SH (China)
  • 2. China Institute of Atomic Energy, Beijing, BJ (China)

Description

Nuclear data is the basis of reactor physics analysis. This paper aim at studying the influence of major evaluated nuclear data libraries, CENDL-3.2, ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0u, on the neutronics modelling of CEFR start-up tests. Results show these four libraries have a good performance and consistency in the modelling CEFR start-up tests. The JEFF-3.3 results exhibit only an 8 pcm keff difference with the measurement. The difference in criticality is decomposed by nuclide, which shows the large overestimation of CENDL-3.2 is mainly from the cross-section of 52Cr. Except for few cases, the calculation results are within 1 s of measurement uncertainty in control rod worth, sodium void reactivity, temperature reactivity, and subassembly swap reactivity. In the evaluation of axial and radial reaction distribution, there are about 65 % of relative errors that are less than 5 % and 82 % of relative errors that are less than 10%

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Technology
Journal Volume
54
Journal Issue
10
Journal Page Range
p. 3888-3896
ISSN
1738-5733

Optional Information

Notes
10 refs, 16 figs, 3 tabs