Standard evaluation techniques for containment and surveillance radiation monitors
Description
Evaluation techniques used at Los Alamos for personnel and vehicle radiation monitors that safeguard nuclear material determine the worst-case sensitivity. An evaluation tests a monitor's lowest sensitivity regions with sources that have minimum emission rates. The result of our performance tests are analyzed as a binomial experiment. The number of trials that are required to verify the monitor's probability of detection is determined by a graph derived from the confidence limits for a binomial distribution. Our testing results are reported in a way that characterizes the monitor yet does not compromise security by revealing its routine performance for detecting process materials
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS. MF A01 as DE82014074.
Files
Additional details
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- LA-UR--82-1106
Conference
- Title
- 4. annual symposium on harmonization and standardization.
- Dates
- 27 - 29 Apr 1982.
- Place
- Petten (Netherlands).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14721151
- Subject category
- S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- MEASURING METHODS; NUCLEAR FACILITIES; PERSONNEL MONITORING; RADIATION MONITORING; RADIATION MONITORS; RADIOACTIVE MATERIALS; SAFEGUARDS; STANDARDIZATION; VEHICLES
- Descriptors DEC
- MATERIALS; MEASURING INSTRUMENTS; MONITORING
Optional Information
- Secondary number(s)
- CONF-820415--4.