Multileaf Collimator Characteristics and Reliability Requirements for IMRT Elekta System
- 1. Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL (United States)
- 2. Sun Nuclear Corporation, Melbourne, FL (Australia)
Description
Understanding the characteristics of a multileaf collimator (MLC) system, modeling MLC in a treatment planning system, and maintaining the mechanical accuracy of the linear accelerator gantry head system are important factors in the safe implementation of an intensity-modulated radiotherapy program. We review the characteristics of an Elekta MLC system, discuss the necessary MLC modeling parameters for a treatment planning system, and provide a novel method to establish an MLC leaf position quality assurance program. To perform quality assurance on 40 pairs of individual MLC leaves is a time-consuming and difficult task. In this report, an effective routine MLC quality assurance method based on the field edge of a backup jaw as referenced in conjunction with a diode array as a radiation detector system is discussed. The sensitivity of this test for determining the relative leaf positions was observed to be better than 0.1 mm. The Elekta MLC leaf position accuracy measured with this system has been better than 0.3 mm
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2007.07.2392Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2007.07.2392;
- PII
- S0360-3016(07)04354-4;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 71
- Journal Issue
- 1
- Journal Page Range
- p. S89-S92
- ISSN
- 0360-3016
- CODEN
- IOBPD3
Conference
- Title
- Challenges of advanced technology
- Acronym
- 2007 interorganizational symposium on quality assurance of radiation therapy
- Dates
- 20-22 Feb 2007
- Place
- Dallas, TX (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40006936
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; COLLIMATORS; LINEAR ACCELERATORS; QUALITY ASSURANCE; RADIATION DETECTORS; RADIOTHERAPY; RELIABILITY; REVIEWS; SIMULATION
- Descriptors DEC
- ACCELERATORS; DOCUMENT TYPES; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; THERAPY
Optional Information
- Copyright
- Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.