Published October 2010
| Version v1
Journal article
Modification of etching properties of a newly developed nuclear track detector called allyl bis-(2-nitroxy-ethyl) carbomate (ABNEC)-allyl diglycol carbonate (ADC) copolymer [ABNEC:ADC (1:9)] by gamma irradiation
- 1. Bhabha Atomic Research Centre, Trombay, Mumbai (India). Radiochemistry Division
- 2. Goa University, Goa (India). Chemistry Department
Description
The gamma irradiation effects on the bulk etch rate, Vb of an indigenously prepared new nuclear track detector which is a copolymer of allyl bis-(2-nitroxy-ethyl) carbomate (ABNEC) and allyl diglycol carbonate (ADC) [ABNEC:ADC (1:9)] were studied in the dose range of 25.0-250.0 kGy and etching temperature range of 60-80 deg C. The bulk etch rates increase and the activation energy values for bulk etching of gamma-irradiated detectors decrease with the increase in gamma dose indicating the scission of the detector. UV-visible spectra of the unirradiated and the irradiated films were also taken to explore the possibility of using this new detector for gamma dose measurements. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Radioanalytical and Nuclear Chemistry
- Journal Volume
- 286
- Journal Issue
- 1
- Journal Page Range
- p. 99-101
- ISSN
- 0236-5731
- CODEN
- JRNCDM
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 41122856
- Subject category
- S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
- Descriptors DEI
- ETCHING; GAMMA RADIATION; RADIATION DETECTORS; TEMPERATURE RANGE 0273-0400 K; ULTRAVIOLET SPECTRA
- Descriptors DEC
- ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; RADIATIONS; SPECTRA; SURFACE FINISHING; TEMPERATURE RANGE
Optional Information
- Notes