Analysis and process of high pressure control valve stem leakage in tianwan nuclear power station

  • 1. Jiangsu Nuclear Power Co., Ltd., Lianyungang (China)

Description

Tianwan nuclear power station since it was put into operation, the steam turbine high pressure control valve has always been the valve stem leakage problem of steam and water spray, serious impact on power plant security and economy. Aiming at the problems for further research and find out the root cause of this phenomenon. From the two aspects of the valve body and steam-extracting system solutions, the axial flow fan and stem bushing design improvements, eventually successful solution the problem. (authors)

Part of:
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.2--nuclear energy & power sub-volume

Additional details

Publishing Information

Publisher
Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
978-7-5022-7103-9
Imprint Title
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.2--nuclear energy & power sub-volume
Imprint Pagination
377 p.
Journal Page Range
p. 198-203

Conference

Title
2015 academic annual meeting of China Nuclear Society
Dates
21-24 Sep 2015
Place
Mianyang (China)

Optional Information

Notes
9 figs., 3 refs.