Published 1993
| Version v1
Report
Open
Testing of a cryogenic recooler heat exchanger at Brookhaven National Laboratory
Description
Brookhaven National Laboratory has tested a recooler heat exchanger intended to be used in the cryogenic system of the Relativistic Heavy Ion Collider. The unit is required to transfer 225 Watts from a supercritical helium stream flowing at 100 g/s to a helium bath boiling at 4.25 K. Measurements made with heat loads of 50 to over 450 Watts on the unit indicate its cooling capacity is greater than 400 Watts, as expected, and it will be suitable for use in the RHIC ring. Presented are the modifications made to BNL's MAGCOOL test facility that were necessary for testing, test procedure, and recooler performance
Availability note (English)
MF available from INIS under the Report Number; Available from OSTI as DE93040166; NTIS; US Govt. Printing Office Dep.Files
25018492.pdf
Files
(199.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:339303690e94e304458dc190f3e874df
|
199.0 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 7 p.
- Report number
- BNL--49347
Conference
- Title
- International cryogenic engineering conference and international cryogenic materials conference.
- Dates
- 12-16 Jul 1993.
- Place
- Albuquerque, NM (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 25018492
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BROOKHAVEN RHIC; CRYOGENICS; HEAT EXCHANGERS; HELIUM DILUTION REFRIGERATION; PERFORMANCE TESTING
- Descriptors DEC
- ACCELERATORS; COOLING; HEAVY ION ACCELERATORS; REFRIGERATION; STORAGE RINGS; TESTING