Published 1984 | Version v1
Book

Chemistry of the secondary circuit

Creators

  • 1. Electricite de France, Production-Transport, 75 - Paris

Description

Study of the various possibilities to prevent the corrosion phenomena in the different parts of the secondary circuit (condenser, water facility, steam lines, turbines and vapor generators): choice of a volatile conditioning with ammonia or morpholine and not with phosphate which concentration in the vapor generators may induce local corrosion, and search for a low oxidizing medium by restriction of the air admission and addition of hydrazine

Abstract (French)

Etude des possibilites de lutte contre les phenomenes de corrosion dans les differentes parties du circuit secondaire (condenseur, poste d'eau ensemble du circuit vapeur, turbine et generateurs de vapeur): adoption d'un conditionnement volatil a l'ammoniaque ou a la morpholine et non au moyen de phosphate dont la concentration dans les generateurs de vapeur entraine des cas de corrosion localisee, et recherche d'un milieu peu oxydant, par limitation des entrees d'air et addition d'hydrazine
Part of:
Proceedings of the meeting on operation experience of French 900 MW PWR units

Additional details

Additional titles

Original title (French)
La chimie du circuit secondaire

Publishing Information

Publisher
SFEN.
Imprint Place
Paris (France)
Imprint Title
Proceedings of the meeting on operation experience of French 900 MW PWR units
Imprint Pagination
407 p.
Journal Page Range
p. 166-177.

Conference

Title
secondary cooling circuit and equipments for turbine hall.
Acronym
SFEN meeting on operation experience of French 900 MW PWR units. 2. Session
Dates
20 Jun 1984.
Place
Paris (France).

Optional Information

Notes
Imprint:Journee experience d'exploitation des tranches nucleaires francaises du palier 900 MW a eau sous pression.;Le circuit secondaire et les materiels de la salle des machines.