A power supply for the ITER Neutral Beam Injector (NBI) is a DC ultra-high voltage (UHV) power supply to accelerate negative ion beams of 40 A up to an energy of 1 MeV. Japan Atomic Energy Agency as the Japan Domestic Agency for ITER contributes procurement of dc -1 MV main components such as step-up -1 MV transformers rectifiers, a high voltage deck 2, a -1 MV insulating transformer, a transmission line, a surge reduction system and equipments for site test. Design of the surge suppression in the NBI power supply is one of the key issues to obtain the stable injector performance. This report describes the design study using EMTDC code on the surge suppression by optimizing the core snubber and additional elements in the -1 MV power supply. The results show that the input energy from the stray capacitance to the accelerator at the breakdown can be reduced to about 25 J that is smaller than design criteria for ITER. (author)

Availability note (English)

Available from JAEA; DOI: https://doi.org/10.11484/jaea-technology-2010-029

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

System files (106.3 kB)

Name Size Download all

Additional details

Publishing Information

Imprint Pagination
68 p.
Report number
JAEA-Technology--2010-029

Optional Information

Notes
6 refs., 45 figs., 36 tabs.