Dipole magnet of injection system for recirculator SALO

Description

Dipole magnet design was developed for the injection system recirculator SALO. Fabricated prototype magnet has a C-shaped structure with rectangular slices. The pole cross section is 100 x 100 mm, aperture - 25 mm. Field distribution in the magnet at the value of the field induction in the magnet gap 0.05 and 0.2 T was measured. We calculated the effective length of the magnet and the multipole components of the magnetic field

Availability note (English)

Available online: http://www1.jinr.ru/Pepan_letters/panl_2012_4-5/19_guk.pdf

Additional details

Additional titles

Original title (Russian)
Дипольный магнит системы инжекции рециркулятора SALO

Publishing Information

Journal Title
Pis'ma v Zhurnal 'Fizika Ehlementarnykh Chastits i Atomnogo Yadra'
Journal Volume
9
Journal Issue
4-5/174-175
Series
Proceedings of the seminar. Edited by I.N.Meshkov
Journal Page Range
p. 672-677
ISSN
1814-5957

Conference

Title
electron-positron colliders. 9. international scientific seminar in memory of V.P.Sarantsev
Original Conference Title
Problemy uskoritelej zaryazhennykh chastits: ehlektron-pozitronnye kollajdery. 9. mezhdunarodnyj nauchnyj seminar pamyati V.P.Sarantseva
Acronym
Problems of charged particle accelerators
Dates
17-21 Sep 2011
Place
Alushta (Ukraine)

INIS

Country of Publication
Joint Institute for Nuclear Research (JINR)
Country of Input or Organization
Joint Institute for Nuclear Research (JINR)
INIS RN
44041892
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM INJECTION; DISTRIBUTION; MAGNET COILS; MAGNETIC DIPOLES; MAGNETIC FIELDS; MAGNETS
Descriptors DEC
DIPOLES; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; MULTIPOLES

Optional Information

Notes
4 refs., 15 figs.