Published September 1993 | Version v1
Journal article

Diagnostics of gas filling of the streamer chamber for the GIBS spectrometer

  • 1. Joint Inst. for Nuclear Research, Dubna (Russian Federation)

Description

The paper analyses the data on diagnostics of gas filling of a streamer chamber of a 1 m3 volume under conditions of its operation at the JINR synchrophasotron. Optimization (in terms of time and cost) of the process of achieving the operating conditions of the chamber and support of this process via computers and multiloop electric circuits with RC-chains is proposed

Additional details

Additional titles

Original title (Russian)
Диагностика газового наполнения стримерной камеры спектрометра GIBS

Publishing Information

Journal Title
Pribory i Tekhnika Ehksperimenta
Journal Issue
no.5
Journal Page Range
p. 43-48.
ISSN
0032-8162
CODEN
PRTEAJ