Vibration of the core barrel is least desirable for safe operation of the PWR reactor. These mechanical vibrations are in correlation with the fluctuations of neutron flux density whose time and frequency analysis serves failure diagnosis. The mathematical model is described of the transfer of mechanical vibrations of the core barrel to neutron noise. Other steps are indicated indispensable for the application of the method of neutron noise analysis for in-service diagnostics of nuclear power plants. (Z.M.)

Additional details

Additional titles

Original title (Czech)
Monitorovani vibraci nosneho valce reaktoru typu VVER vnereaktorovymi ionizacnimi komorami

Publishing Information

Imprint Title
Diagnostics of nuclear power plant components
Imprint Pagination
136 p.
Journal Page Range
p. 49-55.
Report number
INIS-mf--9057

Conference

Title
National seminar on diagnostics of nuclear power plant components.
Dates
23-24 Nov 1981.
Place
Zvikovske Podhradi (Czechoslovakia).

Optional Information

Notes
Imprint:Diagnostika zarizeni jadernych elektraren.;Sbornik referatu z celostatniho seminare.