Published February 1996 | Version v1
Journal article

Microstructure and mechanical properties of cold worked and helium ion implanted steel type Kh16N15M3T at elevated temperatures

Description

Microstructure of cold worked with 20% reduction and helium ion implanted steel type Kh16N15M3T was investigated. Tensile tests at 293, 773, 973 and 1073 K were conducted. It was shown that irradiation caused some additional strengthening in the case of tests at room temperature. Radiation hardening is absent at elevated test temperature. 6 refs., 2 figs., 1 tab

Additional details

Additional titles

Original title (Russian)
Микроструктура и механические свойства при повышенной температуре холоднодеформированной и облученной ионами гелия стали Kh16N15M3T

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
80
Journal Issue
2
Journal Page Range
p. 121-123.
ISSN
0004-7163
CODEN
AENGAB