Measurement of the distance between rectum mucosa and an afterloading applicator by the dose rate of a Co-60-source
- 1. Universitaets-Frauenklinik Hamburg (Germany). Abt. fuer Gynaekologische Radiologie
Description
The appropriate afterloading applicator for HDR-Ir-therapy is used for that purpose. A Co-60-source (370 MBq) with a guiding wire is positioned at the tip of the applicator and then withdrawn in steps of 1 cm. For each of these points the maximum dose at the rectum mucosa is measured with an ionisation chamber. From a reference curve it is then possible to determine the distance from the rectum mucosa to the applicator and to mark it in the calculated isodose plan. The actual daily dose to the rectum mucosa is planned not to exceed 3.0 Gy in the maximum. Up to now the measurements were performed in 91 patients. The minimal distances of the rectum mucosa from the applicator were found to range from 5 to 18 mm with an average value of 14 mm. The comparison of the measurement with the readings of the rectum probe during each session showed, that the method is suitable to avoid an overdose at the rectum mucosa. (orig./MG)
Abstract (German)
Patientinnen mit gynaekologischen Tumoren, die eine intrakavitaere High-dose-rate-afterloadingtherapie erhalten, wird der passende Applikator gelegt. In diesen Applikator wird eine Co-60-Quelle (370 MBq) ueber einen Fuehrungsdraht bis an die Spitze geschoben und in 1-cm-Schritten zurueckgezogen. Fuer jeden dieser Punkte wird mit einer Ionisationskammer die maximale Dosisleistung im Rektum der Patienten gemessen. Aus einer gemessenen Kurve kann dann der Abstand der Rektumschleimhaut vom Applikator bestimmt und in den Isodosenplan eingezeichnet werden. Pro Fraktion soll die Rektumschleimhaut maximal 3.0 Gy erhalten. Bisher wurden an insgesamt 91 Patientinnen die Messungen von der intrakavitaeren Therapie durchgefuehrt. Die minimalen Abstaende der Rektumschleimhaut lagen zwischen 5 und 18 mm mit einem Mittelwert von 14 mm. Der Vergleich dieser Messung mit den Messungen der Rektumsonde waehrend der Afterloadingtherapie zeigt, dass die Methode geeignet ist, eine Ueberdosierung an der Rektumschleimhaut zu vermeiden. (orig./MG)Additional details
Additional titles
- Original title (German)
- Messung des Abstandes der Rektumschleimhaut von einem gynaekologischen Afterloadingapplikator ueber den Dosisleistungsabfall einer Kobalt-60-Quelle
Publishing Information
- Journal Title
- Strahlentherapie und Onkologie
- Journal Volume
- 170
- Journal Issue
- 2
- Journal Page Range
- p. 103-106.
- ISSN
- 0179-7158
- CODEN
- STONE4
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 25072890
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AFTERLOADING; CARCINOMAS; COBALT 60; DIMENSIONS; DOSE RATES; ISODOSE CURVES; MUCOUS MEMBRANES; PATIENTS; RADIATION SOURCES; RECTUM; WOMEN
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; COBALT ISOTOPES; DIGESTIVE SYSTEM; DISEASES; FEMALES; GASTROINTESTINAL TRACT; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; INTESTINES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LARGE INTESTINE; MAMMALS; MAN; MEDICINE; MINUTES LIVING RADIOISOTOPES; NEOPLASMS; NUCLEI; ODD-ODD NUCLEI; ORGANS; PRIMATES; RADIOISOTOPES; RADIOTHERAPY; THERAPY; VERTEBRATES; YEARS LIVING RADIOISOTOPES