Safety analysis of an ancient iron structure
- 1. Research Institute of Industrial Science and Technology, Pohang (Korea, Republic of)
- 2. Exelal Inc., Daejeon (Korea, Republic of)
Description
Safety analysis of an ancient iron structure, Danggan, constructed over than a thousand years ago was performed. The structure is consisted of 24 iron cylinders of which the total height is about 15.4 m. The analysis was done by the ultrasonic test to measure thickness of each cylinder, the radiographic test to investigate the inside of cylinders, the measurement of inclination of the structure and the structural analysis to estimate the stress level applied by the wind. Results showed that Danggan structure was on state being well safe at present, but it could be dangerous when the inclination of the structure becomes severely progressive.
Additional details
Publishing Information
- Publisher
- KSNT
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the Korean Society for Nondestructive Testing Spring Meeting 2002
- Imprint Pagination
- 244 p.
- Journal Page Range
- p. 3-4
Conference
- Title
- 2002 Spring Meeting of the Korean Society for Nondestructive Testing
- Dates
- 8 Nov 2002
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 45113445
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CYLINDERS; IRON; SAFETY; SAFETY ANALYSIS; THICKNESS; ULTRASONIC TESTING
- Descriptors DEC
- ACOUSTIC TESTING; DIMENSIONS; ELEMENTS; MATERIALS TESTING; METALS; NONDESTRUCTIVE TESTING; TESTING; TRANSITION ELEMENTS
Optional Information
- Notes
- 2 figs