Published May 10, 1988 | Version v1
Journal article

Normalization of a collimated 14.7 MeV neutron source in a neutron spectrometry system for benchmark experiments

  • 1. Ben-Gurion Univ. of the Negev, Beersheba (Israel). Dept. of Nuclear Engineering

Description

In the present study a method used to normalize a collimated 14.7 MeV neutron beam is introduced. It combined a measurement of the fast neutron scalar flux passing through the collimator, using a copper foil activation, with a neutron transport calculation of the foil activation per unit source neutron, carried out by the discrete-ordinates transport code DOT 4.2. The geometry of the collimated neutron beam is composed of a D-T neutron source positioned 30 cm in front of a 6 cm diameter collimator, through a 120 cm thick paraffin wall. The neutron flux emitted from the D-T source was counted by an NE-213 scintillator, simultaneously with the irradiation of the copper foil. Thus, the determination of the normalization factor of the D-T source is used for an absolute flux calibration of the NE-213 scintillator. The major contributions to the uncertainty in the determination of the normalization factor, and their origins, are discussed. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
268
Journal Issue
1
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
229-233
ISSN
0168-9002
CODEN
NIMAE