Optimisation of image reconstruction for phase-contrast x-ray Talbot–Lau imaging with regard to mechanical robustness
Creators
- 1. ECAP—Novel Detectors/Medical Physics, Friedrich-Alexander-University Erlangen-Nuremberg, Erwin-Rommel-Strasse 1, Erlangen (Germany)
- 2. Pattern Recognition Lab, Friedrich-Alexander-University Erlangen-Nuremberg, Martensstrasse 3, Erlangen (Germany)
Description
X-ray grating-based phase-contrast imaging opens new opportunities, inter alia, in medical imaging and non-destructive testing. Because, information about the attenuation properties and about the refractive properties of an object are gained simultaneously. Talbot–Lau imaging requires the knowledge of a reference or free-field image. The long-term stability of a Talbot–Lau interferometer is related to the time span of the validity of a measured reference image. It would be desirable to keep the validity of the reference image for a day or longer to improve feasibility of Talbot–Lau imaging. However, for example thermal and other long-term external influences result in drifting effects of the phase images. Therefore, phases are shifting over time and the reference image is not valid for long-term measurements. Thus, artifacts occur in differential phase-contrast images. We developed an algorithm to determine the differential phase-contrast image with the help of just one calibration image, which is valid for a long time-period. With the help of this algorithm, called phase-plane-fit method, it is possible to save measurement-time, as it is not necessary to take a reference image for each measurement. Additionally, transferring the interferometer technique from laboratory setups to conventional imaging systems the necessary rigidity of the system is difficult to achieve. Therefore, short-term effects like vibrations or distortions of the system lead to imperfections within the phase-stepping procedure. Consequently, artifacts occur in all three image modalities (differential phase-contrast image, attenuation image and dark-field image) of Talbot–Lau imaging. This is a problem with regard to the intended use of phase-contrast imaging for example in clinical routine or non-destructive testing. In this publication an algorithm of Vargas et al is applied and complemented to correct inaccurate phase-step positions with the help of a principal component analysis (PCA). Thus, it is possible to calculate the artifact free images. Subsequently, the whole algorithm is called PCA minimization algorithm. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/61/17/6441Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 61
- Journal Issue
- 17
- Journal Page Range
- p. 6441-6464
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 49090758
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ALGORITHMS; ATTENUATION; BIOMEDICAL RADIOGRAPHY; CALIBRATION; COMPLEMENT; GRATINGS; IMAGE PROCESSING; IMAGES; INTERFEROMETERS; MINIMIZATION; NONDESTRUCTIVE TESTING
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; MATERIALS TESTING; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; OPTIMIZATION; ORGANIC COMPOUNDS; PROCESSING; PROTEINS; RADIOLOGY; TESTING