Flow induced response of thermal insulation and its relation to design

  • 1. Central Electricity Generating Board, Berkeley (UK). Berkeley Nuclear Labs.

Description

Thermal insulation is fitted in Gas Cooled Reactors to protect vulnerable coolant circuit components from high temperatures. In particular the inner surface of the concrete pressure vessel is lined in the later Magnox stations and in the Advanced Gas Cooled Reactors. The insulated surface area is 1850 m2 in Hinkley 'B' and 3000 m2 in the segregated vessel design used for the Hartlepool and Heysham stations. Extensive on-site erection is needed involving upwards of 300 men for over 18 months. The cost of the insulation is more than 5% of the reactor cost for an AGR station. Once installed, much of the insulation is physically inaccessible and for this reason and because of radiological restrictions the designs fitted must be able to survive in the gas circuit environment for the full reactor lifetime. Should modifications be necessary for any reason, the economic penalty is very high. Constraints on insulation design arising from turbulent flow pressure forces are described and methods for evaluating the insulation vibration response are discussed. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London (UK)
ISBN
0 7277 0192 4
Imprint Title
Vibration in nuclear plant. Vol. 1. Proceedings of the 3rd international conference on 'vibration in nuclear plant' held on 11-14 May 1982, Keswick (GB)
Journal Page Range
p. 378-420.

Conference

Title
3. international conference on vibration in nuclear plant.
Dates
11-14 May 1982.
Place
Keswick (UK).

Optional Information

Notes
Imprint:Published in 2 vols. (Complete set: ISBN 0 7277 0194 0).