Published October 1980
| Version v1
Journal article
A 20 K cryopump with a high conductance baffle design
Creators
- 1. Rijksuniversiteit Groningen (Netherlands). Kernfysisch Versneller Inst.
Description
To create better vacuum conditions in the central region of a cyclotron a 20 K cryopump has been designed and built with a 100 K baffle optimized for a high conductance and a low radiation input. The transmission of the baffle is 0.5, the pump speed is 8000 l s-1 for nitrogen. The design techniques and the results are described. (author)
Additional details
Publishing Information
- Journal Title
- Vacuum
- Journal Volume
- 30
- Journal Issue
- 10
- Series
- Vacuum.
- Journal Page Range
- 411-414
- ISSN
- 0042-207X
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 12592422
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- CRYOPUMPS; CYCLOTRONS; NITROGEN; RADIANT HEAT TRANSFER; SPECIFICATIONS; THERMAL CONDUCTION; VERY LOW TEMPERATURE
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; ELEMENTS; ENERGY TRANSFER; HEAT TRANSFER; NONMETALS; PUMPS; VACUUM PUMPS