Hydrogen treatment system in the Genkai nuclear power plant No. 2

  • 1. Kyushu Electric Power Co., Inc., Fukuoka (Japan)

Description

The new hydrogen treatment system which injects hydrogen into the volume control tank for purging the mixed waste gas of Kr, Xe, etc. is adopted in the Genkai nuclear power plant No. 2. The system is composed of mainly the waste gas pretreatment equipment, a palladium alloy membrane type hydrogen separator, a hydrogen compressor, and a waste gas decay tank. The outline of the primary cooling system and the chemical volume control system of PWR, the hydrogen treatment system, and the gaseous waste disposal system of original and new types for the Genkai nuclear power plants No. 1 and 2 are explained in this paper. This newly added hydrogen treatment system will be able to reduce the rare gas concentration rate in the primary coolant to about 1/2 and 1/5 for Kr85 and Xe133, respectively. (auth.)

Additional details

Publishing Information

Journal Title
Kenkyu Kiho (Kyushu Denryoku K.K. Sogo Kenkyusho)
Journal Volume
47
Series
Kenkyu Kiho (Kyushu Denryoku K.K. Sogo Kenkyusho).
Journal Page Range
153-155