Published May 1, 2012 | Version v1
Journal article

Observation of parametric X-ray radiation by an imaging plate

  • 1. SAGA Light Source, 8-7 Yayoigaoka, Tosu, Saga 841-0005 (Japan)
  • 2. Kharkov Institute of Physics and Technology, Kharkov 61108 (Ukraine)

Description

We have demonstrated experimentally the application of an imaging plate for registering the angular distribution of parametric X-ray radiation. The imaging plate was used as a two-dimensional position-sensitive X-ray detector. High-quality images of the fine structure in the angular distributions of the yield around the reflection of the parametric X-ray radiation produced in a silicon crystal by a 255-MeV electron beam from a linear accelerator have been observed in the Laue geometry. A fairly good agreement between results of measurements and calculations by the kinematic theory of parametric X-ray radiation is shown. Applications of the imaging plates for the observation of the angular distribution of X-rays produced by accelerated particles in a crystal are also discussed.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nimb.2012.02.021

Additional details

Identifiers

DOI
10.1016/j.nimb.2012.02.021;
PII
S0168-583X(12)00114-0;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms
Journal Volume
278
Journal Page Range
p. 78-81
ISSN
0168-583X
CODEN
NIMBEU

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.