Published May 1982 | Version v1
Report Restricted

BWR Refill-Reflood Program, Task 4.4. 300 SSTF description document

Description

As part of the Boiling Water Reactor (BWR) Refill/Reflood (R/R) program, the 300 SSTF CCFL/Refill System Effects tests will contribute in part to the overall objectives of the Refill/Reflood program: to develop a better understanding of the phenomena controlling the refill and reflood phase of BWR loss of coolant accidents (LOCAs); to provide a basis for and support to the development and qualifications of best-estimate BWR system thermal hydraulic codes for LOCAs; and to provide a basis for assessing assumptions used in establishing BWR LOCA safety margins. The primary role of the SSTF CCFL/Reflood tests will be in providing a data base for assessment of BWR best-estimate separate effect and system models. Inherent in this task is the generation of data addressing the phenomena controlling the refill phase of BWR LOCAs and hydraulic phenomena leading to the initiation of bottom reflood. This data base can also be utilized to address the assumptions and models currently used in evaluation of BWR LOCA conditions

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS. - GPO $7.00 as DE82904675.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
166 p.
Report number
NUREG/CR--2133

Optional Information

Secondary number(s)
EPRI-NP--1584; GEAP--24939.