Published December 2009 | Version v1
Journal article

Handling zone dividing method in packed bed liquid desiccant dehumidification/regeneration process

  • 1. Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084 (China)

Description

Dehumidifier and regenerator are the most significant components in liquid desiccant air-conditioning systems, in which air directly contacts liquid desiccant and heat and mass transfer process occurs between the two fluids. Heat transfer process and mass transfer process within dehumidifier/regenerator influence each other and should not be separately considered. Based on the previous reachable handling region analysis, a zonal method is proposed in present study. Four zones are divided in the psychrometric chart according to the relative position of inlet air to inlet desiccant including two dehumidification zones, zone A and zone D, and two regeneration zones, zone B and zone C. In zone A or C, mass transfer is key process, and counter-flow configuration has the best mass transfer performance and parallel-flow is the poorest in the same operating conditions. In zone B or D, heat transfer is governing process, parallel-flow has the best mass transfer performance and counter-flow is the poorest. In order to obtain better mass transfer performance, liquid desiccant should be cooled (in zone A) rather than air (in zone D) in dehumidifier, and liquid desiccant should be heated (in zone C) rather than air (in zone B) in regenerator. The divided zones and the corresponding zonal properties will be helpful to the design and optimization of dehumidifiers and regenerators.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2009.07.022

Additional details

Identifiers

DOI
10.1016/j.enconman.2009.07.022;
PII
S0196-8904(09)00294-5;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
50
Journal Issue
12
Journal Page Range
p. 3024-3034
ISSN
0196-8904
CODEN
ECMADL

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41074223
Subject category
S42: ENGINEERING;
Descriptors DEI
AIR CONDITIONING; COUNTERFLOW SYSTEMS; DEHUMIDIFIERS; DESICCANTS; DESIGN; HEAT TRANSFER; LIQUIDS; MASS TRANSFER; OPTIMIZATION; PACKED BEDS; REGENERATION; REGENERATORS
Descriptors DEC
ENERGY TRANSFER; FLUIDS