Published January 2022 | Version v1
Journal article

Calculation of attenuation parameter for Ir-192 gamma source in shielding materials

  • 1. School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Terengganu (Malaysia)
  • 2. Oncological and Radiological Science Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang (Malaysia)
  • 3. Department of Physics and Engineering Physics, Obafemi Awolowo University, Ile-Ife (Nigeria)

Description

Purpose: Calculation of photon attenuation is necessary for the selection of shielding materials for an irradiation facility. Methods and Materials: In this work, a Monte Carlo simulation was utilized to assess the effectiveness of clay-polyethylene mixture and clay as the radiation shielding materials for high-energy gamma sources (Ir-192). Ordinary concrete was also studied as the benchmark. Results: The calculated linear attenuation values for ordinary concrete are within 0.44% of the standard XCOM value for 380 keV photon. In the case of a multienergy Ir-192 gamma source, the calculated linear attenuation coefficient (μ) for ordinary concrete is 15.5% and 7.25% higher than clay and fabricated clay-polyethylene, respectively. Meanwhile, the μ value for fabricated clay-polyethylene is 8.3% higher than that of clay. Conclusion: In conclusion, a 10 cm thickness of clay and clay-polyethylene mixture is sufficient to attenuate 87% and 89% of photons from Ir-192 source. The calculated linear attenuation coefficients for the three shielding materials are also consistently higher, about 7.5%, than that of the XCOM value for 380 keV photon. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Medical Physics
Journal Volume
47
Journal Issue
1
Journal Page Range
p. 34-39
CODEN
JMPHFE