Published March 2011
| Version v1
Journal article
Development of bubble measurements by using 4-sensor probe
- 1. Kyoto Univ., Research Reactor Institute, Kumatori, Osaka (Japan)
- 2. Kyoto Univ., Graduate School of Energy Science, Kyoto (Japan)
- 3. Institute of Nuclear Safety System, Inc., Mihama, Fukui (Japan)
Description
A simple algorithm using 4-sensor probe was derived to measure bubble velocity in a gas-liquid two-phase flow. Measurement error of bubble velocity and shape was estimated numerically and experimentally, assuming spherical and ellipsoidal bubble. The result shows that the bubble velocity can be measured within 10% error at 0 < jl < 1.0 [m/s] by using this method. (author)
Availability note (English)
Available from http://dx.doi.org/10.3811/jjmf.24.673Additional details
Identifiers
- DOI
- 10.3811/jjmf.24.673;
Publishing Information
- Journal Title
- Konsoryu
- Journal Volume
- 24
- Journal Issue
- 5
- Journal Page Range
- p. 673-680
- ISSN
- 0914-2843
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 43008090
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ALGORITHMS; BUBBLES; GASES; INTERFACES; LIQUIDS; MONTE CARLO METHOD; NUMERICAL ANALYSIS; PROBES; SENSORS; SHAPE; TWO-PHASE FLOW; VELOCITY
- Descriptors DEC
- CALCULATION METHODS; FLUID FLOW; FLUIDS; MATHEMATICAL LOGIC; MATHEMATICS
Optional Information
- Notes
- 9 refs., 17 figs.