Investigation of the radiation leakage from X ray flaw detectors and the improvement measures for the unqualified products
Description
The authors introduce investigation methods and results for radiation leakage from X ray flaw detectors, which are used in Beijing area. Total 21 sets of flaw detectors made in 8 factories in Beijing, Shanghai etc. have been tested, of which 16 sets made in Beijing, Dandong and Japan are gas cooling flaw detectors, and rest 5 sets made in Shanghai and Germany are water or oil cooling detectors. The air Kerma rate of leakage radiation at 1 m from the X ray tube target were measured by Type FJ-347A X, γ dosimeter. It can be seen from the results that, compared with the trade standard ZBY315-83, 5 sets of water or oil cooling flaw detectors are all qualified. However, only two sets of gas cooling detectors are qualified, and the radiation leakage of another 14 sets are over the values specified in the standard. The reason is analyzed, and some advices about the measures of improving radiation protection structure design and production technology for the unqualified products have been proposed
Additional details
Publishing Information
- Journal Title
- Radiation Protection (Taiyuan)
- Journal Volume
- 17
- Journal Issue
- 1
- Journal Page Range
- p. 62-67.
- ISSN
- 1000-8187
- CODEN
- FUFAEM
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 28045213
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- AIR; KERMA; LEAKS; MODIFICATIONS; RADIATION DETECTORS; RADIATION DOSES; RADIATION MONITORING; RADIATION PROTECTION; X RADIATION; X-RAY DETECTION; X-RAY TUBES
- Descriptors DEC
- DETECTION; ELECTROMAGNETIC RADIATION; ELECTRON TUBES; EQUIPMENT; FLUIDS; GASES; IONIZING RADIATIONS; MEASURING INSTRUMENTS; MONITORING; RADIATION DETECTION; RADIATIONS; X-RAY EQUIPMENT