Validation of CATHENA for flow oscillation in frequency domain

Description

This paper reports on the validation of CATHENA for flow oscillations. The time-dependent results from the flow oscillation experiment and from the CATHENA simulation were detrended and then transferred into the frequency domain using discrete Fourier transform for comparison. Sensitivities of the modelling options and impacts of uncertainties from the code inputs on the predicted key parameter were also assessed in the frequency domain. The reported work demonstrates that the accuracy of CATHENA in predicting flow oscillation frequencies and amplitudes can be assessed precisely in the frequency domain. (author)

Files

49101479.pdf

Files (957.5 kB)

Name Size Download all
md5:4f135e1f548df3f1668c9ecec54c549f
957.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
11 p.
Report number
AECL-CW--125000-CONF-017

Conference

Title
24. Nuclear Simulation Symposium
Dates
14-16 Oct 2012
Place
Ottawa, ON (Canada)

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
49101479
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTER CODES; COMPUTERIZED SIMULATION; FLUID FLOW; FREQUENCY ANALYSIS; OSCILLATIONS
Descriptors DEC
SIMULATION

Optional Information

Notes
2 refs., 4 tabs., 6 figs.