Published 2012
| Version v1
Report
Open
Validation of CATHENA for flow oscillation in frequency domain
Description
This paper reports on the validation of CATHENA for flow oscillations. The time-dependent results from the flow oscillation experiment and from the CATHENA simulation were detrended and then transferred into the frequency domain using discrete Fourier transform for comparison. Sensitivities of the modelling options and impacts of uncertainties from the code inputs on the predicted key parameter were also assessed in the frequency domain. The reported work demonstrates that the accuracy of CATHENA in predicting flow oscillation frequencies and amplitudes can be assessed precisely in the frequency domain. (author)
Files
49101479.pdf
Files
(957.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:4f135e1f548df3f1668c9ecec54c549f
|
957.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 11 p.
- Report number
- AECL-CW--125000-CONF-017
Conference
- Title
- 24. Nuclear Simulation Symposium
- Dates
- 14-16 Oct 2012
- Place
- Ottawa, ON (Canada)
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 49101479
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPUTER CODES; COMPUTERIZED SIMULATION; FLUID FLOW; FREQUENCY ANALYSIS; OSCILLATIONS
- Descriptors DEC
- SIMULATION