Published March 21, 2003 | Version v1
Journal article

The effect of dead-timeless silicon strip readout at CDF II

Description

The Run IIa CDF Silicon Upgrade has recently finished installation. The detector uses revision D of the SVX3 readout IC. This final revision incorporated new features in order to improve the potential of dead-timeless operation. This paper describes measurements of dead-timeless effects on silicon strip readout on the test bench. This paper also describes tests of the dynamic pedestal subtraction circuitry, which is shown to improve greatly the dead-timeless performance of the silicon systems

Additional details

Identifiers

PII
S0168900202020338;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
501
Journal Issue
1
Journal Page Range
p. 197-200
ISSN
0168-9002
CODEN
NIMAER

INIS

Country of Publication
Netherlands
Country of Input or Organization
Syrian Arab Republic
INIS RN
34064141
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
DEAD TIME; FERMILAB COLLIDER DETECTOR; PERFORMANCE; READOUT SYSTEMS; SI SEMICONDUCTOR DETECTORS
Descriptors DEC
MEASURING INSTRUMENTS; RADIATION DETECTORS; SEMICONDUCTOR DETECTORS; TIMING PROPERTIES

Optional Information

Copyright
Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.