Published June 1994 | Version v1
Journal article

Documentation of measuring values of pipeline wall thicknesses

  • 1. Siemens AG, Energieerzeugung KWU, Erlangen (Germany)

Description

Pipelines for water or saturated steam in power plants and the like that are threatened by extensive material thinning, due, for instance, to erosion corrosion, normally are subjected to destruction-free measurements of their remaining wall thicknesses. ''DASY'', the PC-assisted program developed by Siemens/KWU, permits efficient storage, administration, evaluation and documentation of the vast amounts of data acquired, rendering the keeping of record achieves superfluous. (orig.)

Abstract (German)

Wasser- oder nassdampffuehrende Rohrleitungen in Kraftwerken und anderen Anlagen, die durch flaechige Materialabtraege - z.B. infolge Erosionskorrosion - gefaehrdet sind, werden in der Regel hinsichtlich ihrer noch vorhandenen Wanddicken durch zerstoerungsfreie Messungen ueberprueft. Das von Siemens/KWU entwickelte PC-gestuetzte Programm DASY erlaubt in effizienter Weise die Speicherung, Verwaltung, Auswertung und Dokumentation der dabei anfallenden grossen Datenmengen. Eine umfangreiche Archivierung von Protokollen kann damit entfallen. (orig.)

Additional details

Additional titles

Original title (German)
Dokumentation der Wanddickenmesswerte von Rohrleitungen

Publishing Information

Journal Title
TU. Technische Ueberwachung
Journal Volume
35
Journal Issue
6
Journal Page Range
p. 240-243.
ISSN
0376-1185
CODEN
TUSZA6

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
25066935
Subject category
S42: ENGINEERING;
Descriptors DEI
DOCUMENTATION; IN-SERVICE INSPECTION; INFORMATION SYSTEMS; PERSONAL COMPUTERS; PIPELINES; POWER PLANTS; SERVICE LIFE; THICKNESS; WALLS
Descriptors DEC
COMPUTERS; DIGITAL COMPUTERS; DIMENSIONS; INSPECTION; LIFETIME; MICROCOMPUTERS