Published December 2012 | Version v1
Journal article

Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

  • 1. Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)
  • 2. Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)
  • 3. Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore)
  • 4. Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore)
  • 5. Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

Description

Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2012.08.007

Additional details

Identifiers

DOI
10.1016/j.ejrad.2012.08.007;
PII
S0720-048X(12)00391-9;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
81
Journal Issue
12
Journal Page Range
p. 3979-3984
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.