Effect of reactor coolant pumps following a small break in a pressurized water reactor
Description
Small-break loss-of-coolant accidents were calculated to help determine whether to trip the reactor-coolant pumps early in the accident when the reactor scrams or to delay the pump trip (pump trip times ranged from 450 s to no trip at all). Four-in.-diam (approximate) cold-leg breaks in Babcock and Wilcox (B and W) and Westinghouse (W) pressurized-water reactors were investigated using the Transient Reactor Analysis Code, TRAC-PD2. The results indicated that for a 4-in.-diam cold-leg break the optimum mode of pump operation is design dependent. In terms of primary system mass depletion, the case with no pump trip was preferable for the W plant, whereas an early pump trip was preferable for the B and W plant. When the pumps were not operating in the W plant, the loop seals plugged with liquid, leading to a pressure buildup in the upper plenum and, consequently, a high liquid flow through the break. The vent valves in the B and W plant mitigated the consequences of the loop seals plugging; the effect was enough to favor an early pump trip
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01 as DE82021765.
Files
Additional details
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- LA-UR--82-2521
Conference
- Title
- International meeting on thermal nuclear reactor safety.
- Dates
- 29 Aug - 2 Sep 1982.
- Place
- Chicago, IL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14732081
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPUTER CALCULATIONS; HEAT TRANSFER; HYDRAULICS; LOSS OF COOLANT; PUMPS; PWR TYPE REACTORS; REACTOR SAFETY; SPATIAL DISTRIBUTION
- Descriptors DEC
- ACCIDENTS; DISTRIBUTION; ENERGY TRANSFER; EQUIPMENT; REACTOR ACCIDENTS; REACTORS; SAFETY; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-820802--11.