Use of the scanner and 3D dosimetry in the evaluation of dose distribution of prostate carcinomas treatment by association of an interstitial brachytherapy with iridium 192 and an external radiotherapy

  • 1. Centre Francois-Baclesse, Service de Radiophysique, 14 - Caen (France)
  • 2. Centre Francois-Baclesse, Service de Curietherapie, 14 - Caen (France)
  • 3. Institut Gustave Roussy, Service de Physique, 94 - Villejuif (France)

Description

The implementation of this technique leads to a conformational approach of the prostate cancer treatment, by association of brachytherapy and external radiotherapy. The next advance will consist in replacing the classical marking by orthogonal images by a complete visual simulation for the preliminary dosimetry of brachytherapy and external radiotherapy. (N.C.)