Published December 2017 | Version v1
Journal article

Experimental and numerical heat transfer investigation of an impingement jet array with V-ribs on the target plate and on the impingement plate

  • 1. Institute of Aerospace Thermodynamics (ITLR), University of Stuttgart, Pfaffenwaldring 31, Stuttgart 70569 (Germany)
  • 2. Siemens Energy, Inc., Fossil Power Generation, 4400 Alafaya Trail, MC Q3-031, Orlando, FL 32826 (United States)

Description

Highlights: • The numerical and the experimental results show an overall agreement. • The V-rib and the V-rib-impingement configurations increase the Nusselt number. • The V-rib-target configuration is effective due to the target surface enlargement. • The rib induced additional pressure loss is negligible. • The effect of V-ribs on the impingement plate is very promising. - Abstract: The secondary vortex structure of an impingement jet system is enhanced by V-ribs on both the impingement and target plates. Numerical and experimental investigations are conducted to study the flow field and heat transfer resulting from V-rib turbulators in an impingement cooling configuration. Three different cases are tested: V-ribs on both the impingement and target plates (V-rib), V-ribs only on the impingement plate (V-rib-impingement) and V-ribs only on the target plate (V-rib-target). The experiment is carried out on a 9 by 9 inline impingement array test facility. For the transient measurements, narrow band thermochromic liquid crystals (TLC) and thermocouples are applied to obtain the local heat transfer distribution. Pressure taps are used to measure the pressure loss. The numerical simulation is carried out with ANSYS CFX 14, using a steady state Reynolds-Averaged Navier-Stokes (RANS) approach and the Shear Stress Transport (SST) turbulence model. All studies are done for a Reynolds number range of 15,000 to 35,000. There is a good overall agreement between the experimental and numerical results for the cases studied. The detailed flow field from the numerical simulation is used to understand and complement the phenomena observed in the experiment. The evaluation of the flow field confirms that the V-ribs enhance the secondary flow structure in the impingement system and induce a positive heat flux ratio compared to the baseline case. Both experimental and numerical results show a Nusselt number increase for the V-rib-impingement and V-rib configuration, with a highest Nusselt number ratio of 1.16. Notice that the experiment cannot take the rib part into account due to the invalid 1D semi-infinite wall assumption there, while the CFD simulation allows for the consideration of heat transfer on the rib surface and thus complements the heat flux data on the target plate. Depending on the configuration, the CFD simulation shows a heat flux ratio of 1.06–1.34. The pressure loss of the system is comparable to the case with a smooth impingement plate and a smooth target plate.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijheatfluidflow.2017.09.005

Additional details

Identifiers

DOI
10.1016/j.ijheatfluidflow.2017.09.005;
PII
S0142727X17305891;

Publishing Information

Journal Title
International Journal of Heat and Fluid Flow
Journal Volume
68
Journal Page Range
p. 126-138
ISSN
0142-727X
CODEN
IJHFD2

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.