Published 1997 | Version v1
Report Restricted

Preconcentration of low levels of americium and plutonium from waste waters by synthetic water-soluble metal-binding polymers with ultrafiltration

Description

A preconcentration approach to assist in the measurement of low levels of americium and plutonium in waste waters has been developed based on the concept of using water-soluble metal-binding polymers in combination with ultrafiltration. The method has been optimized to give over 90% recovery and accountability from actual waste water

Availability note (English)

Available from INIS in electronic form; ALSO AVAILABLE FROM OSTI AS DE98003718; NTIS; US GOVT. PRINTING OFFICE DEP.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
19 p.
Report number
LA-UR--97-1190

Conference

Title
4. international conference on methods and applications of radioanalytical chemistry
Dates
6-11 Apr 1997
Place
Kona, HI (United States)

Optional Information