Determination of Th, U, Na and K in high-purity tantalum

  • 1. Daido Steel Co. Ltd., Nagoya (Japan)

Description

Trace impurities in high-purity tantalum for ULSI were regulated severely, because they have effect on reliability of element performance. Radioactive elements and alkali metal elements which cause to trouble particularly, have been investigated by ICP-AES, fluorescence spectrometric method, and flameless-AAS after ion-exchange separation method. We examined conditions of ion-exchange separation of the object elements from matrix tantalum, influences of residual tantalum and acids for sample dissolution on measurement and the countermeasure for them, analytical conditions of ICP-AES, and correction method for fluorescence intensity of U, chiefly. The detection limits of the present methods were 2 ppb for Th, 0.5 ppb for U, and 0.01 ppb for Na and K, respectively. (author)

Additional details

Publishing Information

Journal Title
Tetsu To Hagane
Journal Volume
77
Journal Issue
11
Series
Tetsu To Hagane.
Journal Page Range
1929-1935
ISSN
0021-1575
CODEN
TEHAA