Abbreviated protocol for breast MRI: Are multiple sequences needed for cancer detection?
Creators
- 1. Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States)
- 2. Columbia University Medical Center, Herbert Irving Pavilion, 161 Fort Washington Avenue, 10th Floor, New York, NY 10032 (United States)
- 3. New York Medical College, 40 Sunshine Cottage Rd, Valhalla, NY 10595 (United States)
Description
Highlights: • Abbreviated breast MR demonstrates high sensitivity for breast carcinoma detection. • Time to perform/interpret the abbreviated exam is shorter than a standard MRI exam. • An abbreviated breast MRI could reduce costs and make MRI screening more available. - Abstract: Objective: To evaluate the ability of an abbreviated breast magnetic resonance imaging (MRI) protocol, consisting of a precontrast T1 weighted (T1W) image and single early post-contrast T1W image, to detect breast carcinoma. Materials and methods: A HIPAA compliant Institutional Review Board approved review of 100 consecutive breast MRI examinations in patients with biopsy proven unicentric breast carcinoma. 79% were invasive carcinomas and 21% were ductal carcinoma in situ. Four experienced breast radiologists, blinded to carcinoma location, history and prior examinations, assessed the abbreviated protocol evaluating only the first post-contrast T1W image, post-processed subtracted first post-contrast and subtraction maximum intensity projection images. Detection and localization of tumor were compared to the standard full diagnostic examination consisting of 13 pre-contrast, post-contrast and post-processed sequences. Results: All 100 cancers were visualized on initial reading of the abbreviated protocol by at least one reader. The mean sensitivity for each sequence was 96% for the first post-contrast sequence, 96% for the first post-contrast subtraction sequence and 93% for the subtraction MIP sequence. Within each sequence, there was no significant difference between the sensitivities among the 4 readers (p = 0.471, p = 0.656, p = 0.139). Mean interpretation time was 44 s (range 11–167 s). The abbreviated imaging protocol could be performed in approximately 10–15 min, compared to 30–40 min for the standard protocol. Conclusion: An abbreviated breast MRI protocol allows detection of breast carcinoma. One pre and post-contrast T1W sequence may be adequate for detecting breast carcinoma. These results support the possibility of refining breast MRI screening protocols.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2014.10.004Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2014.10.004;
- PII
- S0720-048X(14)00469-0;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 84
- Journal Issue
- 1
- Journal Page Range
- p. 65-70
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47005546
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BIOPSY; CARCINOMAS; COMPARATIVE EVALUATIONS; IMAGES; MAMMARY GLANDS; NMR IMAGING; REFINING; SENSITIVITY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; GLANDS; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.